MFI Pump Belt Adjusting Tool
When the MFI pump drive belt is replaced, the pump mount must be loosened to get the belt on...then the pump must be moved back and the belt tightened. This tool is used to do this. It's a 1/4" thick steel square that I welded into a slot cut into a 1/2", 3/8" drive socket. The steel square piece is placed between the pump body and the side flange on the base...then rotated with a 3/8" socket handle and medium extension...it cams the pump body over and lets you hold the pressure until the bolts are tightened. MFI Pump Tightening Tool (13 kb)